The non-UV-stable grade of Addaset. Identical performance in every respect except that the resin darkens under UV. Specify it only where the colour shift is acceptable or the area is sheltered.
Where it is used
Sheltered pedestrian areasAreas where a darkening resin is acceptable or intendedBudget-driven driveway and patio work
Substrates
Concrete — clean, dry, free of laitance, oil, grease and loose particlesAsphalt — clean and dryJoints reflected through the surface
Application data
Coverage, thickness, mix and cure, as declared by the manufacturer. Site conditions in the Gulf sit at the top of most of these ranges — allow for it in the programme.
ProductPolyurethane resin for resin bound surfacing, non-UV-stable
Density1.02 g/cm³
Application conditions+5 °C to 25 °C, maximum 80% relative humidity
Full chemical cure7 days
PackagingPre-weighed units
StorageAbove 5 °C, out of direct sunlight, wind and rain
Performance data
Every figure below is reproduced from the manufacturer's own technical data sheet, with the test standard it was measured against. The sheet itself is in the download section.
PropertyResultStandard
Third-party assessmentBBA Agrément Certificate as a resin bound aggregate surfacing systemBritish Board of Agrément
Permeability — 3 mm aggregate4.46 – 7.67 L/sec/m² at 12 mm depthBS EN 12697-40:2005
Permeability — 6 mm aggregate7.39 – 20 L/sec/m² at 18 mm depthBS EN 12697-40:2005
Permeability — 10 mm aggregate17 – 30 L/sec/m² at 22 mm depthBS EN 12697-40:2005
Skid resistance — pedestrianSlider 96 > 55TRL 176
Skid resistance — vehicularSlider 57 > 60TRL 176
UV behaviourResin darkens on UV exposureAddagrip data sheet
Where not to use it
The limits are as much a part of the specification as the performance. Everything here is stated on the manufacturer's data sheet.
The resin will darken when exposed to UV — this is inherent, not a defectApplication range is narrower: +5 °C to 25 °CDo not apply in wet conditions
Specification clause
Resin bound surfacing: Addagrip Addaset Non UVR polyurethane resin bound surface course, [10] mm aggregate laid [22] mm thick to the approved sample panel. Contractor to advise the Architect in writing that the resin darkens under UV exposure. Permeability to BS EN 12697-40:2005. Applied between +5 °C and 25 °C. 7 days full chemical cure.
Square brackets mark the choices that belong to the project. Send us the finishes schedule and we will return the clause completed, with the sample and mock-up programme against it.
Documents
Every document is the manufacturer's own, reproduced in full and unaltered under our cover. Free to download, no form.
We supply the material and we apply it, so the specification and the workmanship sit with one party. Send a finishes schedule, an elevation or a mood board and we will come back with the system, the build-up, the sample programme and a completed clause.